Common symptoms and fault codes

Symptoms and quick diagnosis

Boiler losing pressure

Top up via filling loop to 1.0–1.5 bar. If it drops again within days, you likely have a hidden leak or failed expansion vessel.

Radiators cold at the bottom

Sludge build-up. A power flush + magnetic filter usually restores full heat.

Radiators cold at the top

Trapped air — bleed the radiator. If it returns, you may need a power flush or system inhibitor top-up.

No hot water but heating works

Typically diverter valve or DHW thermistor — common, quick fix on most combis.

Hot water lukewarm

Scaled plate heat exchanger or failing diverter — descale or replace.

Banging or kettling noises

Limescale or sludge on the heat exchanger. Don't ignore — it shortens boiler life.

Whistling or gurgling

Air in the system or undersized pump. Bleed rads and check pump speed setting.

Pilot light keeps going out

Thermocouple or gas valve. Don't keep relighting; call a Gas Safe engineer.

Pressure rising on its own

Failed filling loop or expansion vessel pressure loss. Easy fix for an engineer.

Boiler ignites then cuts out

Flame loss — check gas supply, ignition lead and flame sensor. Often a PCB fault on older units.

Condensate pipe frozen

Common in winter. Pour warm (not boiling) water on the external pipe, then reset.

Boiler keeps locking out

Repeated lockouts point to ignition, gas valve or PCB fault. Stop resetting — book an engineer.

Smell of gas

Open windows, turn off the gas at the meter and call the National Gas Emergency line on 0800 111 999 immediately.

Leaking from underneath

Pump seal, heat exchanger or pressure relief valve. Turn the boiler off and call us.

Fault codes by brand

Worcester Bosch

  • EA 227 · Flame loss — gas supply, ignition lead or PCB
  • EA 229 · Flame detected when it shouldn't be — gas valve
  • EA 338 · Ignition fault — spark generator or gas valve
  • E9 · Heating flow temperature too high — pump or sludge
  • H07 · Pressure low — top up via filling loop
  • D1 286 · Return sensor fault
  • C6 269 · Fan speed out of range
  • A1 · Pump not circulating — air or blockage

Vaillant

  • F22 · Low water pressure — repressurise system
  • F23 · Large temperature difference flow/return — pump
  • F24 · Rapid temperature rise — pump airlock or blockage
  • F28 · Ignition failure — gas valve or PCB
  • F29 · Flame lost during operation
  • F62 · Gas valve shutdown delay fault
  • F75 · Pump or pressure sensor fault
  • F83 · Flow/return temperature change too small

Baxi

  • E110 · Boiler overheat — pump or system blockage
  • E118 · Low water pressure
  • E125 · Insufficient circulation
  • E133 · Ignition lockout — gas supply or igniter
  • E160 · Fan fault
  • E168 · PCB communication error
  • E28 · Flue sensor fault

Ideal Heating

  • F1 · Low pressure — repressurise
  • F2 · Flame loss
  • F3 · Fan fault
  • F4 · Flow thermistor fault
  • F5 · Return thermistor fault
  • F9 · PCB fault
  • L2 · Ignition lockout — failed to detect flame
  • L5 · Repeat overheat lockout

Glow-worm

  • F1 · Low water pressure
  • F4 · No flame established
  • F9 · Boiler timing out on heating
  • F22 · Low water pressure
  • F28 · Ignition fault
  • F29 · Flame loss during operation
  • F75 · Pressure sensor / pump fault

Potterton

  • E110 · Overheat lockout
  • E125 · Circulation issue
  • E133 · Ignition lockout
  • E160 · Fan speed fault
  • E168 · Internal PCB error

Viessmann

  • F.4 · No flame detected
  • F.5 · Air pressure switch
  • F.10 · Outdoor sensor fault
  • F.20 · Safety shut-off — overheat
  • F.22 · Pump fault — dry running
  • F.38 · Return sensor short circuit

Alpha

  • E1 · Ignition failure
  • E2 · Overheat
  • E3 · Fan / flue fault
  • E4 · Flow thermistor
  • E10 · Low pressure

Main

  • E110 · Overheat
  • E125 · Poor circulation
  • E133 · Ignition lockout
  • E160 · Fan fault

Ferroli

  • A01 · Ignition lockout
  • A02 · Flame on with gas valve closed
  • A03 · Overheat
  • F37 · Low pressure
  • F39 · External probe fault

Vokera

  • A01 · Ignition lockout
  • A02 · False flame signal
  • A03 · Overheat
  • A04 · Low pressure
  • A06 · DHW thermistor fault

Ariston

  • 1 01 · Overheat
  • 1 03 · Insufficient circulation
  • 1 04 · Insufficient circulation — pump
  • 1 P1 · Pressure low
  • 5 01 · No flame detected
  • 6 01 · Flue gas blocked / fan fault